OurDaikin ventilation solutions include: Heat Reclaim Ventilation (VAM) - Heat and moisture recovery - Free cooling from fresh outdoor air - Available as a separate unit or combine with Sky Air or VRV systems -Energy saving ventilation -Optional CO2 sensor -Optional dust filters ePM10 70% (M6), ePM1 55% (F7), ePM1 70% -Quick installation Ventilationsystems replace stale, contaminated indoor air with re-circulated fresh air with virtually no heat/energy loss or safety risk. Heat Reclaim Ventilator Daikin's unique heat exchange element realizes efficient heat exchange between supply air and exhaust air. CarrierChillers Used with Heat Recovery. Buildings are responsible for 40 percent of total energy consumption. Of the energy consumed in commercial buildings, 43 percent is used for space and water heating. If a more efficient means of providing heat could be implemented it would represent a tremendous opportunity to reduce energy consumption HeatReclaim Ventilator with DX-coil (VKM Series) JavaScript must be enabled. pages list. Animation Your nose works as a kind of heat-recovery ventilation system. When you breathe out (1), your nasal passages are warmed by heat from the outgoing air (2). When you breathe in, the cold incoming air picks up some of this heat (3), which would otherwise have been wasted. As a child, you might have learned that it's better to breathe Dịch Vụ Hỗ Trợ Vay Tiền Nhanh 1s. Product Highlights Product Range Capacities View AR View 360 DX coil cooling capacity Airflow rate 500-950 m3 /h Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. Equipped with a heat reclaim ventilator and a heat exchanger DX coil, VKM series is capable of minimizing room temperature fluctuations. VKM series maintains comfortable indoor air quality IAQ by adding fresh outdoor air having nearly the same temperature and humidity conditions as the indoor air. Thus, VKM ensures optimum comfort and further reduces air conditioning load. VKM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VKM Supply Air duct. Heat Reclaim Ventilator + Heat Exchanger → Comfortable Air Supply Equipped with a heat reclaim ventilator and a heat exchanger, the new VKM series minimizes room temperature fluctuations. A Compact Unit Packed with Daikin’s Cutting-Edge Technologies. Air Conditioning and Outdoor Air Processing Can be Accomplished Using a Single System. When the VKM series units are connected, the total connection capacity index must be 50% to 130% of the capacity index of the outdoor units. Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. Tech specs Specifications ModelVKM50GCVEVKM80GCVEVKM100GCVE Power Consumption Heat Exchange modeW 270/230/170390/335/220440/370/260 Power Consumption Bypass modeW305/260/200390/335/220440/370/260 External static Pressure Pa210/170/140220/180/125170/120/90 Airflow rate m3/h500/500/440750/750/640950/950/820 Sound level Heat Exchange modedB43/ Sound level Bypass modedB43/41/ Temp exchange efficiency %76/76/ Enthalpy exchange efficiency %64/64/6766/66/6862/62/66 DX-coil Capacity kW Dimensions H x W x D387x1764x832387x1764x1214387x1764x1214 Machine weight kg92113115 You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE Air Treatment Equipment CEK HARGA=> KATALOGUE=> SPESIFIKASI=> Heat Reclaim Ventilator — VAM series Model Names VAM150GJVE, VAM250GJVE, VAM350GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVE Improved Enthalpy Efficiency*1 Higher External Static Pressure*2 Enhanced Energy Saving Functions Seri VAM ini memberikan efisiensi entalpi yang lebih tinggi*1, karena kinerja elemen film tipis yang sangat ditingkatkan. Selain itu, tekanan statis eksternal yang ditingkatkan*2 menawarkan lebih banyak fleksibilitas untuk pemasangan. Seiring dengan ketiga peningkatan luar biasa ini, operasi pendinginan malam hari gratis berkontribusi pada konservasi energi dan lingkungan yang lebih nyaman. Product Highlights View AR View 360 Fresh air supply and better indoor air quality for confined space. Air flow rate 150 – 2,000 m³/hour Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also curbs the load on the air conditioning system and conserves energy. In addition, the HRV is interlocked to Daikin’s VRV system, SkyAir and other air conditioning systems and automatically switches over ventilation mode, further increasing the effects of energy conservation. HRV operation has been centralized on the air conditioner remote controller allowing total control over air conditioning and ventilation with a simple configuration. VAM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VAM Supply Air duct. Heat Recovery Ventilation with Simultaneous Supply and Exhaust A compact unit packed with Daikin’s cutting-edge technologies The heat exchange element uses a upgraded High Efficiency Paper HEP that has superior moisture-absorption and humidifying properties and doubles the current efficiency of moisture absorption. The heat exchange unit speedily recovers heat contained as latent heat vapor. The element is made of a material with superior flame-resistant properties and is treated with an anti-molding agent. Advanced Energy-Saving Ventilation by Interlocking with VRV Indoor Unit • Pre-cool, Pre-heat control • Auto-ventilation mode changeover switching • Night-time free cooling operation Air Conditioning Load Reduced by Approximately 31%* Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE Product categoryVRV Air Conditioner›Heat Reclaim VentilationModel HRV VAM250GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVESpecificationMODELVAM250GJVEVAM500GJVEVAM650GJVEVAM800GJVEVAM1000GJVEVAM1500GJVEVAM2000GJVEPower Supply1-phase, 220-240 V/ 220 V, 50 HzTemp. ExchangeEf ciency50/60 HzUltra-High%75/7574/7475/7572/7278/7872/7277/77High75/7574/7475/7572/7278/7872/7277/77Low79/7980/ ciency50/60 HzFor HeatingUltra-High%71/7267/ CoolingUltra-High%63/6355/5561/6161/6164/6461/6162/62High63/6355/5561/6161/6164/6461/6162/62Low66/6659/ HzHeatExchangeModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Bypass ModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Sound Level 50/60 HzHeat ExchangeModeUltra-HighdBA27-29/ ModeUltra-HighdBA steel plateInsulation MaterialSelf-extinguishable polyurethane foamDimensions HXWXDmm278X810X551306X879X800338X973X832387X1,111X832387X1,111X1,214785X1,619X832785X1,619X1,214Machine Weighkg2432455567129157Heat Exchange SystemAir to air cross ow total heat Sensible heat+latent heat exchangeHeat Exchange Element MaterialSpecially processed non-ammable paperAir FilterMultidirectional brous eecesFanTypeSirocco fanAir ow Rate50/60 HzUltra-Highm3/h250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000High250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000Low155/155320/295500/470700/670860/8401,320/1,2601,720/1,580External Static Pressure50/60 HzUltra-HighPa70/96105/15085/125133/170168/192112/150116/ Duct Diametermmø150ø 200ø 250ø 350Unit ambient condition-15°C–50°CDB, 80%RH or lessAS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.

daikin heat reclaim ventilator